Standard Specification for Cold-Weather Admixture Systems
This specification covers cold-weather admixture systems to be added to hydraulic-cement concrete when the temperature of the concrete immediately after placement will be low.
This specification stipulates tests of the cold-weather admixture system with suitable materials specified or with materials proposed for specific work, and provides three levels of testing.
The apparatus used shall be suitable for low temperature environment.
The concrete, cementitious materials, aggregates, and air-entraining admixture shall be tested and shall conform to the values of chemical and performance requirements such as initial setting time, compressive strength, shrinkage, durability.
1.1 This specification covers cold-weather admixture systems to be added to hydraulic-cement concrete when the temperature of the concrete immediately after placement will be as low as -5.0 °C [23.0 °F] prior to the time of initial set.
1.2 This specification stipulates tests of the cold-weather admixture system with suitable materials as described in 11.1 – 11.3 or with materials proposed for specific work (See 11.5). Unless otherwise requested by the purchaser, tests shall be made using suitable concreting materials as described in 11.1 – 11.3.
Note 1: Whenever practicable, tests should be made using the concreting materials, the mixture proportions, and batching sequence proposed for the specific work (See 11.5) because the time of setting, compressive strength gain, and other properties may vary.
1.3 This specification provides three levels of testing.
1.4 The text of this standard refers to notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this standard.
1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.6 The following precautionary caveat pertains to the test methods portion, Sections 11 – 18, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.2
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Failed to load document history.
| Publish Date | Document Id | Type | View |
|---|