Standard Guide for Total Measurement Uncertainty Estimation and Reporting for Nondestructive Assay Measurements
1.1 This guide covers the methodologies and best practices for developing and reporting total measurement uncertainty (TMU) estimates for non-destructive assay (NDA) measurements, instruments, calculations, or systems while adapting the principles of JCGM 100 or GUM to meet the uncertainty quantification needs of NDA.
1.2 Guidance is provided on testing and evaluating uncertainty estimates.
1.3 This guide applies to neutron-, photon-, and heat-based NDA methods.
1.4 Both stochastic modeling and analytical uncertainty estimation methods are covered.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
5.1 Adopting a consistent UQ framework based on commonly accepted scientific methods across all NDA techniques promotes a better understanding and implementation of both the NDA techniques and the UQ process. This supports measurement and reporting that is consistent with good practices.
5.2 To be meaningful, a physical measurement or calculation shall be accompanied by a justifiable and scientifically based statement of its associated TMU. The TMU is the fundamental statement of the measurement’s quality.
5.3 Constructing and verifying the magnitude of each TMU component suitable for the end user is often a complex and specialized task. This process is crucial for understanding the limitations and acceptability of the results.
5.4 This guide is intended to serve as a resource and reference for:
5.5 TMU estimates are necessary for the regulatory acceptance of measurement results.
5.6 TMU estimation is also important for various other purposes, such as:
5.7 Inhomogeneous items can be assayed by NDA techniques (for example, calorimetry) in contrast to destructive analysis (DA) techniques that require homogeneity or have large sampling uncertainty.
5.8 NDA can be used in situ while preserving sample integrity.
5.9 NDA often relies much more heavily on process knowledge compared to DA.
5.10 Sampling errors, such as those in holdup measurements and isotopic sampling combined with bulk analysis, differ from those in DA and are typically less significant because the entire item is assayed as a whole.