ASTM D1117-99

Current Revision
Standard Guide for Evaluating Nonwoven Fabrics

Best Price Guarantee Sep 10, 2001 English 3 Pages

Sub Total (1 Item(s)) $ 0.00
Estimated Shipping $ 0.00
Total (Pre-Tax) $ 0.00

You own the digital copy of this edition

View in Library
or
ASTM D1117-99 PDF Preview
ASTM D1117-99

1.1 This guide covers procedures for testing nonwoven fabrics.

The test procedures appear in the following sections:

  • Abrasion Resistance - 18
  • Absorbency - 21
  • Air Permeability - 8
  • Breaking Force and Elongation - 9
  • Bursting Strength - 10
  • Conditioning - 7
  • Dimensional Change - 20
  • Drycleaning - 11
  • Flexural Rigidity - 12
  • Mass Per Unit Area (Note 2) - 17
  • Resin Binder Distribution - 22
  • Seam Breaking Strength - 13
  • Trapezoid Tear - 14
  • Tongue Tear (Single Rip) - 15
  • Elmendorf Tear - 16
  • Thickness - 19

Note 2β€”The terms "machine" and "cross machine" must be substituted for "warp" and "filling," respectively, throughout these test methods wherever pertinent.

1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only and may be approximate.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.1 This guide covers procedures for testing nonwoven fabrics.

The test procedures appear in the following sections:

Section
Abrasion Resistance18
Absorbency21
Air Permeability8
Breaking Force and Elongation9
Bursting Strength10
Conditioning7
Dimensional Change20
Drycleaning11
Flexural Rigidity12
Mass Per Unit Area (Note 2)17
Resin Binder Distribution22
Seam Breaking Strength13
Trapezoid Tear14
Tongue Tear (Single Rip)15
Elmendorf Tear16
Thickness19

Note 2 β€” The terms "machine" and "cross machine" must be substituted for "warp" and "filling," respectively, throughout these test methods wherever pertinent.

1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only and may be approximate.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Loading...

Failed to load document history.

Publish Date Document Id Type View