ASTM D1186-93

Current Revision
Standard Test Methods for Nondestructive Measurement of Dry Film Thickness of Nonmagnetic Coatings Applied to a Ferrous Base

Best Price Guarantee Jul 10, 2001 English 5 Pages

This Document Has Been Superseded

A newer publication replaces it: ASTM D7091


Sub Total (1 Item(s)) $ 0.00
Estimated Shipping $ 0.00
Total (Pre-Tax) $ 0.00

You own the digital copy of this edition

View in Library
or
ASTM D1186-93 PDF Preview
ASTM D1186-93

1.1 These test methods cover the nondestructive measurement of the dry film thickness of nonmagnetic coatings applied over a ferrous base material using commercially available test instruments.

The test methods cover the use of instruments based on magnetic measuring principles only.

Test Method A provides for the measurement of films using magnetic pull-off gages and Test Method B provides for the measurement of films using magnetic flux gages.

1.2 These test methods are not applicable to coatings that will be readily deformable under the load of the measuring instruments, as the instrument probe must be placed directly on the coating surface to take a reading.

1.3 The values given in SI units of measurement are to be regarded as the standard. The values in parentheses are for information only.

1.4 This standard does not purport to address all of the safety problems, if any, associated with its use.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.1 These test methods cover the nondestructive measurement of the dry film thickness of nonmagnetic coatings applied over a ferrous base material using commercially available test instruments. The test methods cover the use of instruments based on magnetic measuring principles only. Test Method A provides for the measurement of films using magnetic pull-off gages and Test Method B provides for the measurement of films using magnetic flux gages.

1.2 These test methods are not applicable to coatings that will be readily deformable under the load of the measuring instruments, as the instrument probe must be placed directly on the coating surface to take a reading.

1.3 The values given in SI units of measurement are to be regarded as the standard. The values in parentheses are for information only.

1.4 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.