Standard Test Method for Standard Penetration Test (SPT) and Split-Barrel Sampling of Soils
1.1 This test method describes the procedure, generally known as the Standard Penetration Test (SPT), for driving a split-barrel sampler with a 140 lb [63.5 kg] hammer dropped 30 in. [750 mm] to obtain a soil sample for identification purposes, and measure the resistance of the soil to penetration of the standard 2 in. [50 mm] diameter sampler. The SPT “N” value is the number of hammer blows required to drive the sampler over the depth interval of 0.5 to 1.5 ft [0.15 to 0.45 m] of a 1.5 ft [0.45 m] drive interval.
1.2 Test Method D4633 is generally necessary to measure the drill rod energy of a given drop hammer system and using the measured drill rod energy, N values can be corrected to a standard energy level. Practice D6066 uses Test Methods D1586 and D4633 and has additional requirements for hammers, hammer energy, and drilling methods to determine energy corrected penetration resistance of loose sands for liquefaction evaluation.
1.3 Practice D3550/D3550M is a similar procedure using a larger diameter split barrel sampler driven with a hammer system that may allow for a different hammer mass. The penetration resistance values from Practice D3550/D3550M do not comply with this standard.
1.4 Test results and identification information are used in subsurface exploration for a wide range of applications such as geotechnical, geologic, geoenvironmental, or geohydrological explorations. When detailed lithology is required for geohydrological investigations, use of continuous sampling methods (D6282/D6282M, D6151/D6151M, D6914/D6914M) are recommended when the incremental SPT N value is not needed for design purposes (see 4.1.1).
1.5 Penetration resistance testing is typically performed at 5 ft [1.5 m] depth intervals or when a significant change of materials is observed during drilling, unless otherwise specified.
1.6 This test method is limited to use in nonlithified soils and soils whose maximum particle size is approximately less than one-half of the sampler diameter.
1.7 This test method involves use of rotary drilling equipment (Guide D5783, Practice D6151/D6151M). Other drilling and sampling procedures (Guides D6286 and D6169/D6169M) are available and may be more appropriate. Considerations for hand driving or shallow sampling without boreholes are not addressed. Subsurface investigations should be recorded in accordance with Practice D5434. Samples should be preserved and transported in accordance with Practice D4220/D4220M using Group B. Soil samples should be identified by group name and symbol in accordance with Practice D2488.
1.8 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026, unless superseded by this test method.
1.8.1 The procedures used to specify how data are collected/recorded and calculated in the standard are regarded as the industry standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the user’s objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations. It is beyond the scope of these test methods to consider significant digits used in analysis methods for engineering data.
1.9 Units—The values stated in either inch-pound or SI units [presented in brackets] are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Reporting of test results in units other than inch-pound shall not be regarded as nonconformance with this practice. SI equivalent units shown herein are in general conformance with existing international standards.
1.10 Penetration resistance measurements often will involve safety planning, administration, and documentation. This test method does not purport to address all aspects of exploration and site safety.
1.11 Performance of the test usually involves use of a drill rig; therefore, safety requirements as outlined in applicable safety standards (for example, OSHA regulations,2 NDA Drilling Safety Guide,3 drilling safety manuals, and other applicable local agency regulations) must be observed.
1.12 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.13 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
1.1 This test method describes the procedure, generally known as the Standard Penetration Test (SPT), for driving a split-barrel sampler with a 140 lb [63.5 kg] hammer dropped 30 in. [750 mm] to obtain a soil sample for identification purposes, and measure the resistance of the soil to penetration of the standard 2 in. [50 mm] diameter sampler. The SPT “N” value is the number of hammer blows required to drive the sampler over the depth interval of 0.5 to 1.5 ft [0.15 to 0.45 m] of a 1.5 ft [0.45 m] drive interval.
1.2 Test Method D4633 is generally necessary to measure the drill rod energy of a given drop hammer system and using the measured drill rod energy, N values can be corrected to a standard energy level. Practice D6066 uses Test Methods D1586 and D4633 and has additional requirements for hammers, hammer energy, and drilling methods to determine energy corrected penetration resistance of loose sands for liquefaction evaluation.
1.3 Practice D3550/D3550M is a similar procedure using a larger diameter split barrel sampler driven with a hammer system that may allow for a different hammer mass. The penetration resistance values from Practice D3550/D3550M do not comply with this standard.
1.4 Test results and identification information are used in subsurface exploration for a wide range of applications such as geotechnical, geologic, geoenvironmental, or geohydrological explorations. When detailed lithology is required for geohydrological investigations, use of continuous sampling methods (D6282/D6282M, D6151/D6151M, D6914/D6914M) are recommended when the incremental SPT N value is not needed for design purposes (see 4.1.1).
1.5 Penetration resistance testing is typically performed at 5 ft [1.5 m] depth intervals or when a significant change of materials is observed during drilling, unless otherwise specified.
1.6 This test method is limited to use in nonlithified soils and soils whose maximum particle size is approximately less than one-half of the sampler diameter.
1.7 This test method involves use of rotary drilling equipment (Guide D5783, Practice D6151/D6151M). Other drilling and sampling procedures (Guides D6286 and D6169/D6169M) are available and may be more appropriate. Considerations for hand driving or shallow sampling without boreholes are not addressed. Subsurface investigations should be recorded in accordance with Practice D5434. Samples should be preserved and transported in accordance with Practice D4220/D4220M using Group B. Soil samples should be identified by group name and symbol in accordance with Practice D2488.
1.8 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026, unless superseded by this test method.
1.8.1 The procedures used to specify how data are collected/recorded and calculated in the standard are regarded as the industry standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the user’s objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations. It is beyond the scope of these test methods to consider significant digits used in analysis methods for engineering data.
1.9 Units—The values stated in either inch-pound or SI units [presented in brackets] are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Reporting of test results in units other than inch-pound shall not be regarded as nonconformance with this practice. SI equivalent units shown herein are in general conformance with existing international standards.
1.10 Penetration resistance measurements often will involve safety planning, administration, and documentation. This test method does not purport to address all aspects of exploration and site safety.
1.11 Performance of the test usually involves use of a drill rig; therefore, safety requirements as outlined in applicable safety standards (for example, OSHA regulations,2 NDA Drilling Safety Guide,3 drilling safety manuals, and other applicable local agency regulations) must be observed.
1.12 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.13 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
4.1 This test is the most frequently used subsurface exploration drilling test performed worldwide. Numerous international and national standards are available for the SPT which are in general conformance with this standard.6
The test provides samples for identification purposes and provides a measure of penetration resistance which can be used for geotechnical design purposes. Many local and widely published international correlations which relate blow count, or N-value, to the engineering properties of soils are available for geotechnical engineering purposes.
4.1.1 Incremental SPT sampling is not a preferred method of soil sampling for environmental or geohydrological exploration unless the SPT N-value is needed for design purposes. Continuous sampling methods such as Direct Push Soil Sampling (Guide D6282/D6282M), or continuous coring using Hollow-Stem Augers (Practice D6151/D6151M) or Sonic Drills (Practice D6914/D6914M) provide the best continuous record of lithology.
Continuous sampling can be performed with SPT samplers, but it is slow compared to other methods, and N values may unreliable (see 4.6.1). Sampling for detailed lithology can be reduced by using screening tests such as geophysics and Direct Push profiling tests such as Cone Penetrometers (Test Method D5778), Dynamic Cone Penetrometer, or electrical resistivity probe.
4.2 SPT N values are affected by many variables allowed in the design and execution of the test (see Appendix X1). Investigations of energy transmission in SPT testing began in the 1970’s and showed that differing drop hammer systems provide different energies to the sampler at depth.
There are so many different hammer designs that it is important to obtain the energy transfer ratio (ETR) for the hammer system being used according to Test Method D4633. ETR of various hammer systems has shown to vary between 45 to 95 % of maximum Potential Energy (PE). Since the N-value is inversely proportional to the energy delivered, resulting N values from different systems are far from standard.
It is now common practice to correct N values to an energy level of 60 % of total (PE), or N60 values as presented here and in Practice D6066. In this standard it is not required to report ETR or N60 but strongly advised to be noted and reported if available.
If ETR of the hammer/anvil/rod system is known, the hammer PE can still vary after calibration, thus it is essential that hammer drop heights/rates be monitored to confirm consistent performance. Report any occurrence of hammer drop heights that do not meet the required value of 30 in. [750 mm] during testing.
Using previous ETR data for a hammer system does not assure that it will perform the same on the current project. If onsite ETR is not obtained, be sure to check hammer drop height/rates to assure the hammer is operating the same as when previously checked.
4.2.1 Other mechanical variables and drilling errors can also adversely affect the N value as discussed in X1.4. Drilling methods can have a major effect on testing (see 4.5). While the SPT hammer system is standardized knowing ETR, drilling methods are not, and a variety of drilling methods can be used.
4.3 SPT is applicable to a wide range of soils. For nomenclature on soil in terms of N-value refer to Appendix X2 for consistency of clays (cohesive soils) and relative density of sands (cohesionless soils) as proposed by Terzaghi and Peck and used commonly in geotechnical practice.
SPT drilling can be performed easily using a variety of drilling methods in denser soils but has some difficulty in softer and looser soils. This test method is limited to non-lithified or un-cemented soils and soils whose maximum particle size is approximately one-half of the sampler diameter or smaller.
Large particles result in higher blow counts and may make the data unsuitable for empirical correlations with finer soils. For example, chamber tests on clean sands have shown coarse sands have higher blow counts than medium fine sands (see X1.6).
In gravelly soils, with less than 20 % gravel, liquefaction investigations may require recording of penetration per blow in an attempt to extrapolate the results to sand blow counts (see X1.7).
Soil deposits containing gravels, cobbles, or boulders typically result in penetration refusal, damage to the equipment, and unreliable N values if gravel plugs the sampler.
4.3.1 Sands—SPT is widely used to determine the engineering properties of drained clean sands during penetration. Obtaining “intact” soil samples of clean sands for laboratory testing is difficult and expensive (see thin walled tube, Practice D1587/D1587M), so engineers use penetration results in sands for predicting engineering properties (Appendix X1).
Appendix X2 and X1.6 provides some estimated properties of sands. There are problems with SPT in loose sands below the water table since they are unstable during drilling.
Practice D6066 provides restricted drilling methods for SPT in loose sands for evaluating earthquake liquefaction potential. Practice D6066 method relies on mud rotary drilling, casing advancers, and fluid filled hollow-stem augers.
4.3.2 Clays—SPT is easy to perform in clays of medium to stiff consistency and higher using a variety of drilling methods. SPT is unreliable in soft to very soft clays because the clay, yields or “fails” under the static weight of the rods alone, or weight of rods and hammer before the test is started.
This problem is accentuated by the heavier weights of automatic hammer assemblies (see X1.3.1.4) but can be alleviated with automatic hammers which are designed to float over the anvil (see 5.4.2.1).
There is such a large variation in possible N values in soft clays it is well accepted that SPT is a poor predictor of the undrained shear strength of clay.
It is recommended to evaluate soft clays with more appropriate methods such as CPT (Test Method D5778), vane shear (Test Method D2573/D2573M), and/or Thin-Wall Tube sampling (Practice D1587/D1587M) and laboratory testing.
4.4 Hammer Drop System—SPT can be performed with a wide variety of hammer drop systems. Typical hammer systems are listed below in order of preference of use:
4.
Failed to load document history.
| Publish Date | Document Id | Type | View |
|---|