ASTM D3645-15(2023)

Current Revision
Standard Test Methods for Beryllium in Water

Best Price Guarantee Dec 1, 2023 English 8 Pages

Sub Total (1 Item(s)) $ 0.00
Estimated Shipping $ 0.00
Total (Pre-Tax) $ 0.00

You own the digital copy of this edition

View in Library
or
ASTM D3645-15(2023) PDF Preview
ASTM D3645-15(2023)

1.1 These test methods cover the determination of dissolved and total recoverable beryllium in most waters and wastewaters:

 

Concentration
Range

 
Sections

Test Method A–Atomic Absorption,  Direct

10 μg/L to 500 μg/L

 7 to 17

Test Method B–Atomic Absorption,  Graphite Furnace

10 μg/L to 50 μg/L

18 to 26

1.2 The analyst should direct attention to the precision and bias statements for each test method. It is the user's responsibility to ensure the validity of these test methods for waters of untested matrices.

1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 12 and 24.4.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

1.1 These test methods cover the determination of dissolved and total recoverable beryllium in most waters and wastewaters:

 

Concentration
Range

 
Sections

Test Method A–Atomic Absorption,  Direct

10 μg/L to 500 μg/L

 7 to 17

Test Method B–Atomic Absorption,  Graphite Furnace

10 μg/L to 50 μg/L

18 to 26

1.2 The analyst should direct attention to the precision and bias statements for each test method. It is the user's responsibility to ensure the validity of these test methods for waters of untested matrices.

1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 12 and 24.4.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

4.1 These test methods are significant because the concentration of beryllium in water must be measured accurately in order to evaluate potential health and environmental effects.