1.1 This test method measures the permeation of liquids and gases through protective clothing materials under the condition of intermittent contact.
1.2 This test method is designed for use when the test chemical is a gas or a liquid, where the liquid is either volatile (that is, having a vapor pressure greater than 1 mm Hg at 25 °C) or soluble in water or another liquid that does not interact with the clothing material.
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
1.1 This test method measures the permeation of liquids and gases through protective clothing materials under the condition of intermittent contact.
1.2 This test method is designed for use when the test chemical is a gas or a liquid, where the liquid is either volatile (that is, having a vapor pressure greater than 1 mm Hg at 25 °C) or soluble in water or another liquid that does not interact with the clothing material.
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
5.1 This test method is used to measure chemical permeation through specimens of protective clothing under the condition of intermittent contact of a test chemical with the specimen. In many applications, protective clothing is contacted intermittently to chemicals, not continuously as is tested by Test Method F739.
5.2 This test method is normally used to evaluate flat specimens and seams from finished items of protective clothing and of materials that are candidates for items of protective clothing.
5.3 In some cases, it may be of interest to compare permeation behaviors that occur under conditions of intermittent contact with those that occur during continuous contact. Test Method F739 is recommended for measuring permeation under the conditions of continuous contact of the test chemical with the protective clothing specimen.
5.4 The breakthrough detection time, standardized breakthrough time, and the cumulative permeation are key measures of the effectiveness of a clothing material to be a barrier to the test chemical. Such information is used in the comparison of clothing materials during the process of selecting clothing for protection from hazardous chemicals. Long breakthrough detection times and standardized breakthrough times and low amounts of cumulative permeation are characteristics of more effective barrier materials than materials with higher permeation characteristics.
Note 1: At present, there is limited quantitative information about acceptable levels of dermal contact with most chemicals. Therefore, the data obtained using this test method cannot be used to infer safe exposure levels.
Note 2: It is possible to relate cumulative permeation test results to the total amount of chemical to which an individual wearer may be exposed by accounting for the exposed surface area and the underlying air layer. This information has potential value when there are known maximum permitted skin exposure doses for specific chemicals.
5.5 The sensitivity of the test method in detecting low permeation rates or amounts of the test chemical permeated is determined by the combination of: (1) the analytical technique and collection system selected, and (2) the ratio of material specimen area to collection medium volume or flow rate.
5.6 Comparison of results of tests performed with different permeation test systems requires specific information on the test cell, procedures, contact and purge times, and analytical techniques. Results obtained from closed-loop and open-loop testing may not be directly comparable.
5.7 While this method specifies standardized breakthrough time as the time at which the permeation rate reaches 0.1 μg/cm2/min, it is acceptable to continue the testing and also report a normalized breakthrough time at a permeation rate of 1.0 µg/cm2/min.
5.8 A group of chemicals that is commonly used in permeation testing is given in Guide F1001.
5.9 Guide F1194 provides a recommended approach for reporting permeation test results.
Failed to load document history.
| Publish Date | Document Id | Type | View |
|---|