1.1 This specification covers factory-made poly(vinylidene fluoride) (PVDF) plastic-lined ferrous metal pipe and fittings, primarily intended for conveying corrosive liquids and gases. Requirements for materials, workmanship, dimensions, design, construction, working pressures and temperatures, test methods, and markings are included.
Note 1 - This specification does not include products coated with PVDF nor does it define the suitability of PVDF-lined components in chemical environments.
1.2 The ferrous piping products shall meet the requirements of the relevant specification listed in 1.2.1. Nominal sizes from 1 through 10 in. in 150 and 300-psi ratings are covered.
1.2.1 For Ferrous Pipe:
1.2.2 For Ferrous Flanges:
1.2.3 For Ferrous Fittings:
1.3 The PVDF-lined flanged pipe and fitting assemblies are limited to use from -18 to 135°C (0 to 275°F)</em>. For use below -18°C (0°F) consult the manufacturer. Use in specific aggressive environments may alter the above temperature range. The operating temperature limits shall be established by mutual agreement between the purchaser and the seller.</p>
1.1 This specification covers factory-made poly(vinylidene fluoride) (PVDF) plastic-lined ferrous metal pipe and fittings, primarily intended for conveying corrosive liquids and gases. Requirements for materials, workmanship, dimensions, design, construction, working pressures and temperatures, test methods, and markings are included.
Note 1-This specification does not include products coated with PVDF nor does it define the suitability of PVDF-lined components in chemical environments.
1.2 The ferrous piping products shall meet the requirements of the relevant specification listed in 1.2.1. Nominal sizes from 1 through 10 in. in 150 and 300-psi ratings are covered.
1.2.1 For Ferrous Pipe:
1.2.2 For Ferrous Flanges:
1.2.3 For Ferrous Fittings:
1.3 The PVDF-lined flanged pipe and fitting assemblies are limited to use from -18 to 135°C (0 to 275°F)</strong>. For use below -18°C (0°F) consult the manufacturer. Use in specific aggressive environments may alter the above temperature range. The operating temperature limits shall be established by mutual agreement between the purchaser and the seller.</p>