Lifts for the transport of persons and goods -- Global essential safety requirements (GESRs)
This document
specifies GESRs for lifts (elevators), their components and functions, and
establishes a system and provides methods for minimizing safety risks that can arise in the course of, the operation and use of, or work on, lifts (elevators).
NOTE 1 Hereinafter, the term “lift? is used instead of the term “elevator?.
NOTE 2 See Clause 5 regarding the use and application of this document.
This document is applicable to lifts that are intended to carry persons or persons and goods that can:
be located in any permanent and fixed structure or building, except lifts located in means of transport, (e.g. ships);
have any
rated load, size of load carrying unit and speed, and
travel distance and number of landings;
be affected by fire in the load-carrying unit (LCU), earthquake, weather, or flood;
be foreseeably misused (e.g. overloaded) but not vandalized.
This document does not cover
all needs of users with disabilities;1 or
risks arising from
work on lifts under construction, testing, or during alterations and dismantling;
use of lifts for fire fighting and emergency evacuation;
vandalism; and
fire outside the LCU.
1 Although the GESRs specified in this document have been identified and evaluated by risk assessment, not all disabilities or combinations of such disabilities of users have necessarily been addressed.