IEC 61557-16 Ed. 2.0 b:2023

Current Revision
Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 16: Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment

Best Price Guarantee Aug 1, 2023 EN/FR 46 Pages

Sub Total (1 Item(s)) $ 0.00
Estimated Shipping $ 0.00
Total (Pre-Tax) $ 0.00
View in Library
or
International Electrotechnical Commission Logo

IEC 61557-16 Ed. 2.0 b:2023

Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 16: Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment

PUBLISH DATE 2023
PAGES 46
IEC 61557-16 Ed. 2.0 b:2023

Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures.

Part 16: Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment.

IEC 61557-16:2023 specifies the requirements applicable to the performance for test and measurement equipment in order to determine the effectiveness of the protective measures for electrical equipment and/or medical electrical equipment described in IEC 62353.

This International Standard is to be used in conjunction with IEC 61557-1:2019.

IEC 61557-16:2023 cancels and replaces the first edition published in 2014. This edition constitutes a technical revision.

This edition includes the following significant technical changes with respect to the previous edition:

  • a) splitting of uncertainty requirements for medical and non-medical electrical equipment in 4.2.1;
  • b) addition of a definition of ranges with defined uncertainty in 4.2.1 to 4.2.7;
  • c) addition of an optional measuring device (MD) for non-medical devices in 4.2.1;
  • d) addition of a limitation of the maximum intrinsic uncertainty for medical applications at leakage current in 4.2.1;
  • e) change of 4.2.3 from test sockets to sockets for service purposes;
  • f) addition of a warning in the operating instructions;
  • g) integration of former 6.3 into 6.2;
  • h) update of Table 1;
  • i) alignment of the structure with that of the whole IEC 61557 series.