PUBLISH DATE 2015
PAGES 20
IEEE 1835-2014

New IEEE Standard - Inactive-Reserved.

This standard provides a procedure that shall be used to:

  • (1) assess structures for atmospheric corrosion;
  • (2) assess the level of risk to the structure in terms of corrosion attack and degradation to the existing coating system;
  • (3) make informed decisions based on those findings as to whether coating repair is needed and if so, to what extent; and
  • (4) apply repair coatings to the structure if applicable.

This standard applies to the repair of above-grade atmospheric coatings. For the purposes of this standard, the atmospheric area to be coated is generally comprised of that portion of the utility support structure above the transition zone.

This standard is limited to the above-grade and atmospheric portions of utility support structures. It does not address below-grade coating repair within and below the transition zone. This standard does not address foundations or guy anchoring systems.

This standard does not cover the coating of aluminum, weathering steel, concrete, or any material other than steel. Likewise, it does not cover the coating of non-support structures such as fencing, buildings, transformers, or other miscellaneous components within the transmission, distribution, and substation systems.

This standard does not cover new construction, transition zone, below-grade, or water immersion. These areas of concern are addressed specifically in other NACE/IEEE standards.

This standard does not address mechanical or structural damage, mechanical or structural repairs, or structural integrity.

This standard provides a procedure that shall be used to (1) assess structures for atmospheric corrosion; (2) assess the level of risk to the structure in terms of corrosion attack and degradation to the existing coating system; (3) make informed decisions based on those findings as to whether coating repair is needed, and if so, to what extent; and (4) apply repair coatings to the structure if applicable.

This standard applies to the repair of above-grade atmospheric coatings.

For the purposes of this standard, the atmospheric area to be coated generally comprises of that portion of the utility support structure above the transition zone, which is that portion of the coating exposed up to 600 mm (24 in) above grade.

This standard serves as a resource for preparing specifications to achieve the successful coating of utility structures.

SDO IEEE: Institute of Electrical and Electronics Engineers
Document Number 1835
Publication Date May 1, 2015
Language en - English
Page Count 20
Revision Level
Supercedes
Committee Transmission and Distribution
Loading...

Failed to load document history.

Publish Date Document Id Type View