IEEE 85-1973

Withdrawn Revision
IEEE Test Procedure for Airborne Sound Measurements on Rotating Electric Machinery

Best Price Guarantee Sep 18, 1986 English 21 Pages

Sub Total (1 Item(s)) $ 0.00
Estimated Shipping $ 0.00
Total (Pre-Tax) $ 0.00

You own the digital copy of this edition

View in Library
or
Institute of Electrical and Electronics Engineers Logo

IEEE 85-1973

IEEE Test Procedure for Airborne Sound Measurements on Rotating Electric Machinery

PUBLISH DATE 1986
PAGES 39
IEEE 85-1973

Revision Standard - Inactive-Withdrawn.

Approved methods for conducting tests and reporting results to effect the uniform determination of rotating-electric-machine sound under steady-state conditions with an accuracy of ± 3 dB are defined.

Three acoustical environments are considered: free field, reverberant field, and semi reverberant field.

Installation and operation of the machine is discussed.

The test procedure assumes the presence of pure tones or the predominance of discrete frequencies in the sound spectrum.

This test procedure defines approved methods for conducting tests and reporting results to effect the uniform determination of rotating electric machine sound under steady-state conditions with an accuracy of + 3 dB tested in these acoustical environments:

  • Free field
  • Reverberant field
  • Semi reverberant field

This procedure assumes the presence of pure tones or the predominance of discrete frequencies in the sound spectrum.