IEEE C37.13-2024

Current Revision
IEEE Standard for Low‐Voltage AC (1058 V and Below) Power Circuit Breakers Used in Enclosures

Best Price Guarantee Dec 20, 2024 English 91 Pages

Sub Total (1 Item(s)) $ 0.00
Estimated Shipping $ 0.00
Total (Pre-Tax) $ 0.00

You own the digital copy of this edition

View in Library
or
Institute of Electrical and Electronics Engineers Logo

IEEE C37.13-2024

IEEE Standard for Low‐Voltage AC (1058 V and Below) Power Circuit Breakers Used in Enclosures

PUBLISH DATE 2024
PAGES 91
IEEE C37.13-2024

Revision Standard - Active.

The following enclosed low-voltage ac power circuit breakers are covered in this standard:

  • a) stationary or drawout type of two-, three-, or four-pole construction, with one or more rated maximum voltages of 1058 V, 730 V, 635 V (600 V for units incorporating fuses), 508 V, or 254 V for application on systems having nominal voltages of 1000 V, 690 V, 600 V, 480 V, or 240 V;
  • b) unfused or fused circuit breakers;
  • c) manually or power operated; and
  • d) with or without electromechanical or electronic trip devices.

Service conditions, ratings, functional components, temperature limitations and classifications of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, application, and the preferred ratings are discussed in this standard.

This standard covers the following types and preferred ratings for enclosed low-voltage ac power circuit breakers:

  • a) Stationary-mounted or drawout-mounted type of two-, three-, or four-pole construction with one or more rated maximum voltages of 1058 V, 730 V, 635 V (600 V for units incorporating fuses), 508 V, or 254 V for application on systems having nominal voltages of 1000 V, 690 V, 600 V, 480 V, or 240 V respectively
  • b) Unfused or fused type
  • c) Manually operated or power operated, with or without a trip system
  • d) Fused drawout-mounted assemblies consisting of current-limiting fuses in a drawout-mounted assembly intended to be connected in series with a low-voltage ac power circuit breaker to form a nonintegrally fused circuit breaker

In this standard, the term circuit breaker shall mean enclosed low-voltage ac power circuit breaker, either fused or unfused.

The term unfused circuit breaker shall mean a circuit breaker without either integrally or nonintegrally mounted fuses, and the term fused circuit breaker shall mean a circuit breaker incorporating current-limiting fuses, whether integrally mounted or nonintegrally mounted.

This standard:

  • a) Establishes minimal functional requirements.
  • b) Establishes preferred rating structure.
  • c) Provides preferred ratings.