BSI BS EN 61558-2-10:2014

Safety of transformers, reactors, power supply units and combinations thereof -- Particular requirements and tests for separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V
Best Price Guarantee
Instant

$228.85

2-5 Days

$228.85

SAVE 10%

$411.93


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


or
British Standards Institution Logo

BSI BS EN 61558-2-10:2014

Safety of transformers, reactors, power supply units and combinations thereof -- Particular requirements and tests for separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V

PUBLISH DATE 2014
PAGES 20
BSI BS EN 61558-2-10:2014

Replacement:

This part of IECĀ 61558 deals with the safety of separating transformers with high insulation level and separating transformers with output voltages exceeding 1Ā 000Ā V. Transformers incorporating electronic circuits are also covered by this standard.

NOTEĀ 1

Safety includes electrical, thermal and mechanical aspects.

Unless otherwise specified, from here onward, the term transformer covers separating transformers with high insulation level and separating transformers with output voltages exceeding 1Ā 000Ā V a.c or 1Ā 500Ā V d.c .

This PartĀ 2-10 is applicable to stationary or portable, single-phase or polyphase, air-cooled (natural or forced) independent or associated dry-type transformers. The windings may be encapsulated or non-encapsulated.

This standard is applicable to transformers and power supply (linear) with internal operational frequencies not exceeding 500Ā Hz.

This standard used in combination with PartĀ 2-16 for switch mode power supply units ( SMPS) is also applicable to power supplies with internal operational frequencies higher than 500Ā Hz. Where the two requirements are in conflict the most severe take precedence.

The rated supply voltage does not exceed 1Ā 000Ā V a.c., and the rated supply frequency and the internal operating frequency do not exceed 500Ā Hz.

The rated output does not exceed:

  • 25Ā kVA for single-phase transformers;

  • 40Ā kVA for polyphase transformers.

This PartĀ 2-10 is applicable to transformers without limitation of the rated output subject to an agreement between the purchaser and the manufacturer.

Where applicable the no-load output voltage or the rated output voltage:

  • does not exceed 1Ā 000Ā V a.c. or 1Ā 500Ā V d.c. for separating transformers with high insulation level;

  • does exceed 1Ā 000Ā V a. c or 1Ā 500Ā V d.c. and does not exceed 15Ā 000Ā V a.c. or 15Ā 000Ā V d.c. for separating transformer with output voltage exceed 1Ā 000Ā V.

This PartĀ 2-10 is not applicable to:

  • transformers covered by IECĀ 60076‑11 ;

  • neon transformers covered by IECĀ 61050 and

  • power supplies and converters for use with or in products according to IECĀ 61347‑2‑10 .

This PartĀ 2-10 is not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers.

Transformers covered by this PartĀ 2-10 are used only in applications where double or reinforced insulation between circuits is not required by the installation rules or by the end product standard.

NOTEĀ 2

Normally, the transformers are intended to be used with equipment to provide voltages different from the supply voltage for the functional requirements of the equipment. The protection against electric shock can be provided (or completed) by other features of the equipment, such as the body. Parts of output circuits can be connected to the input circuits or to protective earth.

This PartĀ 2-10 is applicable to transformers associated with specific equipment, to the extent decided upon by the relevant IEC technical committees.

NOTEĀ 3

Attention is drawn to the following:

  • for transformers intended to be used in vehicles, on board ships, and aircraft, additional requirements (from other applicable standards, national rules, etc.) can be necessary;

  • measures to protect the enclosure and the components inside the enclosure against external influences such as fungus, vermin, termites, solar-radiation, and icing can also be considered;

  • the different conditions for transportation, storage, and operation of the can also be considered;

  • additional requirements in accordance with other appropriate standards and national rules can be applicable to transformers intended for use in special environments, such as tropical environment.

NOTEĀ 4

Future technological development of transformers can necessitate a need to increase the upper limit of the frequencies, until then this PartĀ 2-10 can be used as a guidance document.

SDO BSI: British Standards Institution
Document Number EN 61558-2-10
Publication Date Aug. 31, 2014
Language en - English
Page Count 20
Revision Level
Supercedes
Committee PEL/96
Publish Date Document Id Type View
Aug. 31, 2014 BS EN 61558-2-10:2014 Revision